- High Rejection
- Sea Water Membranes
- LFC Membranes for Low Fouling
- SanRO Membranes for Sanitary or Full Fit
ESPA
|
Test
Conditions |
| The
stated performance is initial
(data taken after 30 minutes
of operation), based on
the following conditions: |
|
|
| NaCl
Solution, PPM* |
1500 |
| Applied
Pressure**,
psig (MPa) |
150
psi (1.05) |
| Operating
Temperature, °F (°C) |
77°
(25°) |
| Permeate
Recovery |
15% |
| pH
Range |
6.5-7.0 |
| *ESPA4
NaCl Solution tested at
500 PPM |
| **ESPA4
tested at 100 psig |
|
 |
| Application
Data |
|
|
| Maximum
Applied Pressure, psig (MPa) |
600
(4.14) |
| Maximum
Feed Flow, GPM (m3/h) |
4040-16(3.6),
8-inch-75(17.0) |
| Maximum
Operating Temperature, °F
(°C) |
113°
(45°) |
| Feedwater
pH Range* |
3.0-10.0 |
| Maximum
Feedwater Turbidity, NTU |
1.0 |
| Maximum
Feedwater SDI (15 mins) |
5.0 |
| Maximum
Chlorine Concentration, PPM |
<0.1 |
| Maximum
Ratio of Concentrate to Permeate
Flow for Any Element |
5:1 |
| Maximum
Pressure Drop for Each Element,
psig |
10 |
| *See
technical literature for extended
pH tolerance |
| |
Hydranautics
High Rejection |
 |
| ESPA1-4040 |
4"x40"
FRP |
2,600 |
99.3 |
Download |
| ESPA2-4040 |
4"x40"
FRP |
1,900 |
99.6 |
Download |
| ESPA3-4040 |
4"x40"
FRP |
3,000 |
98.5 |
Download |
| ESPA4-4040 |
4"x40"
FRP |
2,500 |
99.2 |
Download |
| ESPA1 |
8"x40"
FRP |
12,000 |
99.3 |
Download |
| ESPA2 |
8"x40"
FRP |
9,000 |
99.6 |
Download |
| ESPA2+ |
8"x40"
FRP |
9,000 |
99.6 |
Download |
| ESPA3 |
8"x40"
FRP |
14,000 |
98.5 |
Download |
| ESPA4 |
8"x40"
FRP |
12,000 |
99.2 |
Download |
| ESPAB |
8"x40"
FRP |
8,600 |
99.2 |
Download |
|
| *ESPA4
NaCl Solution Tested at 500 PPM |
|
|
| CPA |
| Test
Conditions |
| The
stated performance is initial (data
taken after 30 minutes of operation),
based on the following conditions: |
| |
| NaCl
Solution, PPM |
1500 |
| Applied
Pressure, psig (MPa) |
225
psi (1.55) |
| Operating
Temperature, °F (°C) |
77°
(25°) |
| Permeate
Recovery |
15% |
| pH
Range |
6.5-7.0 |
| |
| Application
Data |
| |
| Maximum
Applied Pressure, psig (MPa) |
600
(4.14) |
| Maximum
Feed Flow, GPM (m3/h) |
4040-16(3.6),
8-inch-75(17.0) |
| Maximum
Operating Temperature, °F (°C) |
113°
(45°) |
| Feedwater
pH Range* |
3.0-10.0 |
| Maximum
Feedwater Turbidity, NTU |
1.0 |
| Maximum
Feedwater SDI (15 mins) |
5.0 |
| Maximum
Chlorine Concentration, PPM |
<0.1 |
| Maximum
Ratio of Concentrate to Permeate Flow
for Any Element |
5:1 |
| Maximum
Pressure Drop for Each Element, psig
|
10 |
| *See
technical literature for extended pH
tolerance |
| |
 |
|
| Typical
CPA2 systems show stable performance
over element lifetime. Membranes are
durable, cleanable and reliable or a
wide range of operating and feedwater
conditions. |
 |
|
|
| Hydranautics
Sea Water Membranes |
|
|
| Hydranautics
LFC Membranes for Low Fouling |
| Hydranautics
SanRO Membranes for Sanitary or Full Fit
|
| Hydranautics
ESNA Membranes for Nano Filtration |
|
|
|
 |
|
|