Hydranautics CPA Membranes
CPA
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
NaCl Solution, PPM 1500
Applied Pressure, psig (MPa) 225 psi (1.55)
Operating Temperature, °F (°C) 77° (25°)
Permeate Recovery 15%
pH Range 6.5-7.0
 
Application Data
Maximum Applied Pressure, psig (MPa) 600 (4.14)
Maximum Feed Flow, GPM (m3/h) 4040-16(3.6), 8-inch-75(17.0)
Maximum Operating Temperature, °F (°C) 113° (45°)
Feedwater pH Range* 3.0-10.0
Maximum Feedwater Turbidity, NTU 1.0
Maximum Feedwater SDI (15 mins) 5.0
Maximum Chlorine Concentration, PPM <0.1
Maximum Ratio of Concentrate to Permeate Flow for Any Element 5:1
Maximum Pressure Drop for Each Element, psig 10
*See technical literature for extended pH tolerance
Model Number
Description
GPD Nom. Salt Rej., %
CPA2-4040
4"x40" FRP
2,250
99.5
CPA2
8"x40" FRP
10,000
99.7
CPA3
8"x40" FRP
11,000
99.7
CPA4
8"x40" FRP
6,000
99.7
Typical CPA2 systems show stable performance over element lifetime. Membranes are durable, cleanable and reliable or a wide range of operating and feedwater conditions.