| Test
Conditions |
| |
| |
| NaCl
Solution, PPM |
1500 |
| Applied
Pressure, psig (MPa) |
225
psi (1.55) |
| Operating
Temperature, °F (°C) |
77°
(25°) |
| Permeate
Recovery |
15% |
| pH
Range |
6.5-7.0 |
| |
| Application
Data |
| |
| Maximum
Applied Pressure, psig (MPa) |
600
(4.14) |
| Maximum
Feed Flow, GPM (m3/h) |
8-inch
-75(17.0) |
| Maximum
Operating Temperature, °F (°C) |
113°
(45°) |
| Feedwater
pH Range* |
3.0-10.0 |
| Maximum
Feedwater Turbidity, NTU |
1.0 |
| Maximum
Feedwater SDI (15 mins) |
5.0 |
| Maximum
Chlorine Concentration, PPM |
<0.1 |
| Maximum
Ratio of Concentrate to Permeate Flow for Any Element |
5:1 |
| Maximum
Pressure Drop for Each Element, psig |
10 |
| *See
technical literature for extended pH tolerance |
| |