| Test Conditions | |
|---|---|
|
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions: |
|
| NaCl Solution, PPM | 1500 |
| Applied Pressure, psig (MPa) | 225 psi (1.55) |
| Operating Temperature, °F (°C) | 77° (25°) |
| Permeate Recovery | 15% |
| pH Range | 6.5-7.0 |
| Application Data | |
| Maximum Applied Pressure, psig (MPa) | 600 (4.14) |
| Maximum Feed Flow, GPM (m3/h) | 4040-16(3.6), 8-inch-75(17.0) |
| Maximum Operating Temperature, °F (°C) | 113° (45°) |
| Feedwater pH Range* | 3.0-10.0 |
| Maximum Feedwater Turbidity, NTU | 1.0 |
| Maximum Feedwater SDI (15 mins) | 5.0 |
| Maximum Chlorine Concentration, PPM | <0.1 |
| Maximum Ratio of Concentrate to Permeate Flow for Any Element | 5:1 |
| Maximum Pressure Drop for Each Element, psig | 10 |
| *See technical literature for extended pH tolerance | |
![]() |
|
|||||||||||||||||||||||||
|