| Product | Part Number | Active area ft2 (m2) |
Feed spacer thickness (mil) |
Permeate flow rate gpd (m3/d) |
Stabilized salt rejection (%) |
Minimum salt rejection (%) |
|---|---|---|---|---|---|---|
| BW30FR-400 | 202681 | 400 (37) | 28 | 10,500 (40) | 99.5 | 99.0 |
| Product | A | B | C |
|---|---|---|---|
| BW30FR-400 | 40.0 (1,016) | 1.125 (29) | 7.9 (201) |
Operating Limits:
a Maximum temperature for continuous operation above pH 10 is 95˚F (35˚C).
b Refer to Cleaning Guidelines in specification sheet 609-23010.
c Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, Dow Water & Process Solutions recommends removing residual free chlorine by pretreatment prior to membrane exposure.