FILMTEC BW30HR-440i Membrane Elements

 BW30HR-440i

Introduction:
  • Produces 20 percent more water compared to the BW30-400 element, and 10 percent more water compared to the BW30-440i element, at the same operating pressure and with higher rejection, enabling lower capital expense for new systems, or increased water production in an existing system.
  • The BW30HR membrane sheet sustains maximum rejection over the useful life of the RO element of critical solutes, including silica, boron, ammonium and nitrate.
  • Includes iLEC™ (interlocking endcaps) technology, which reduce system operating costs and the risk of o-ring leaks that can cause decreased permeate water quality.
  • Designed using an industry standard 1.125 inch ID permeate tube for interchangeability with other brackish water elements.
Product Specifications
Product Part Number Active area
ft2 (m2)
Feed spacer
thickness (mil)
Permeate flow rate
gpd (m3/d)
Stabilized salt
rejection (%)
Minimum salt
rejection (%)
BW30FR-365 440 (41) 28 12,650 (48) 99.70 99.40
Solute Typical rejection (%)   NH4+ NO3- SiO2 Boron
  99.0 98.5 99.9 83.0

Dimensions – inches (mm)
Product A B C D
BW30FR-365 40.0 (1,016) 40.5 (1,029) 7.9 (201) 1.125 ID (29)

Operating Limits:

  • Membrane Type…………………………………………………… Polyamide Thin-Film Composite
  • Maximum Operating Temperaturea ……………………………...113˚F(45˚C)
  • Maximum Operating Pressure…………………………………… 600 psig (41 bar)
  • Maximum Pressure Drop………………………………………… 15 psig (1.0 bar)
  • pH Range, Continuous Operationa……………………………… 2 - 11
  • pH Range, Short-Term Cleaning (30 min.)b……………………. 1 - 13
  • Maximum Feed Flow……………………………………………… 85 gpm (19 m3/hr)
  • Maximum Feed Silt Density Index………………………………..SDI 5
  • Free Chlorine Tolerancec………………………………………….<0.1 ppm

a Maximum temperature for continuous operation above pH10 is 95˚F (35˚C).

b Refer to Cleaning Guidelines in specification sheet 609-23010.

cUnder certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, Dow Water & Process Solutions recommends removing residual free chlorine by pretreatment prior to membrane exposure

Pure Aqua manufactures and supplies RO systems, and as a leading RO supplier in the sphere of development and implementation of
reverse osmosis and water treatment systems, Pure Aqua earned a great industry reputation in the RO market.
In all commercial and industrial RO systems that Pure Aqua supplies, we include a cleaning procedures in the operating and installation manual.
Pure Aqua, as a leader RO supplier, has a presence all over the world with a strong dealership network to help our customers.

© 2011 Pure Aqua, Inc. All Rights Reserved.