Filmtec BW30-365-FR elements have purified high biofouling feed waters since 1997. Customers have experienced lower operating costs by using Filmtec fouling resistant elements due to their superior fouling resistance and cleanability.

Features:
The BW30-365-FR element features:
A system designer can take advantage of this high productivity, high rejection, fouling resistant reverse osmosis (RO) element in any system design where the potential of high biofouling is expected. In addition, existing installations that are experiencing high biofouling or frequent cleanings can be upgraded by retrofitting to the Filmtec BW30-365-FR element. In either case Filmtec BW30-365-FR elements can reduce the operating costs in most biofouling cases by lowering membrane fouling, reducing average system operating pressure, and extending membrane life.
Specifications:
|
Membrane Type: |
Polyamide Thin-Film Composite (TFC) |
|
Maximum Operating Temperature: |
113F (45C) |
|
Maximum Operating Pressure: |
600 psi (41 bar) |
|
Maximum Pressure Drop: |
15 psi (1.0 bar) |
|
Maximum Feed Flow Rate: |
70 gpm (16 m3/hr) |
|
pH Range, Continuous Operation: |
2-11*** |
|
pH Range, Short-Term Cleaning: |
1-13* (30min) |
|
Maximum Feed Silt Density Index: |
5 SDI |
|
Free Chlorine Tolerance: |
<0.1 ppm** |
|
Permeate Flow Rate: |
9,500 GPD (36 m3/day)* |
|
Stabilized Salt Rejection: |
99.5% |
*Permeate flow and salt rejection based on the following standard conditions: 2,000 ppm NaCl, 225 psi (15.3 bar), 77°F (25°C), pH 8 and 15% recovery. Flow rates for individual elements may vary but will be no more than 7% below the value shown.
**Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, Dow recommends removing residual free chlorine by pretreatment prior to membrane exposure. Most RO systems have carbon pre-filters for this purpose.
***Maximum temperature for continuous operation above pH 10 is 95F (35C).
Note: Active surface area guaranteed +/-3%. Active area as stated by Filmtec is not comparable to nominal membrane area often stated by some manufacturers.
Dimensions:
A: 40.0" (1,016mm) B: 1.125"ID (29mm) C: 7.9" (201mm) |
|
Pure Aqua manufactures and supplies RO systems, and as a leading RO supplier in the sphere of development and implementation of
reverse osmosis and water treatment systems, Pure Aqua earned a great industry reputation in the RO market.
In all commercial and industrial RO systems that Pure Aqua supplies, we include a cleaning procedures in the operating and installation manual.
Pure Aqua, as a leader RO supplier, has a presence all over the world with a strong dealership network to help our customers.