| Test Conditions | |
|---|---|
| The stated performance is intial (data taken after 30 minutes of operation), based on the following conditions: | |
| NaCl Solution, PPM | 32,000 |
| Applied Pressure, psig (MPa) | 800 psi (5.5) |
| Operating Temperature, °F (°C) | 77° (25°) |
| Permeate Recovery | 10% |
| pH Range | 6.5 - 7.0 |
| Application Data | |
| Maximum Applied Pressure, psig (MPa) | 1200 (8.27) |
| Maximum Feed Flow, GPM (m3/h) | 4040-16(3.6), 8-inch-75(17.0) |
| Maximum Operating Temperature, °F (°C) | 113° (45°) |
| Feedwater pH Range* | 3.0-10.0 |
| Maximum Feedwater Turbidity, NTU | 1.0 |
| Maximum Feedwater SDI (15 mins) | 5.0 |
| Maximum Chlorine Concentration, PPM | <0.1 |
| Maximum Ratio of Concentrate to Permeate Flow for Any Element | 5:1 |
| Maximum Pressure Drop for Each Element, psig | 10 |
| *See technical literature for extended pH tolerance | |