SWC5-4040 Hydranautics Membrane

SWC5-4040


Performance

  • Permeate Flow: 1,900 gpd (7.2 m3/d)
  • Salt Rejection: 99.7% (99.5% minimum)

Type
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Membrane Active Area: 85 ft2 (7.9m2)

Application Data*

  • Maximum Applied Pressure: 1200 psig** (8.27 MPa)
  • Maximum Chlorine Concentration: < 0.1 PPM
  • Maximum Operating Temperature: 113 °F (45 °C)
  • pH Range, Continuous (Cleaning): 2-11 (1-13)*
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0
  • Maximum Feed Flow: 16 GPM (3.6 m3/h)
  • Minimum Recovery for any Element: 10 %
  • Maximum Pressure Drop for Each Element: 10 psi

* The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.


Test Conditions

  • The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
  • 32,000 ppm NaCl
  • 800 psi (5.5 MPa) Applied Pressure
  • 77 °F (25 °C) Operating Temperature
  • 10% Permeate Recovery
  • 6.5 - 7.0 pH Range

A, inches (mm) B, inches (mm) C, inches (mm) Weight, lbs. (kg)
40.0 (1016) 3.95 (100.3) 0.75 (19.1) 8 (3.6)

Pure Aqua manufactures and supplies RO systems, and as a leading RO supplier in the sphere of development and implementation of
reverse osmosis and water treatment systems, Pure Aqua earned a great industry reputation in the RO market.
In all commercial and industrial RO systems that Pure Aqua supplies, we include a cleaning procedures in the operating and installation manual.
Pure Aqua, as a leader RO supplier, has a presence all over the world with a strong dealership network to help our customers.

© 2011 Pure Aqua, Inc. All Rights Reserved.